Raynor 3850RGD Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Garagentor-Öffner Raynor 3850RGD herunter. Admiral II Instruction Manual PDF file Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Serial Number:
Date of Purchase:
Belt Drive Garage Door Opener
Raynor Garage Doors
1101 E. River Road
Dixon, Illinois 61021
www.raynor.com
Write down the following information
for future reference:
NOTE: If you are installing the garage door opener on a one-piece door, visit
www.raynor.com for installation instructions.
Contents
Model 8550RGD
FOR RESIDENTIAL USE ONLY
PREPARATION ........................... 2-3
ASSEMBLY ...............................4-5
INSTALLATION ........................ 6-13
INSTALL THE DOOR CONTROL .....14-16
INSTALL THE
PROTECTOR SYSTEM
®
..............17-20
POWER ................................21-22
ADJUSTMENT.........................23-25
BATTERY BACKUP ...................26-27
OPERATION ...............................28
FEATURES.................................29
DOOR CONTROL .....................30-31
REMOTE CONTROL ..................32-33
TO ERASE THE MEMORY ...............33
TO OPEN THE DOOR MANUALLY ......34
MAINTENANCE ...........................34
TROUBLESHOOTING ................. 35-36
REPAIR PARTS .......................37-38
ACCESSORIES ............................39
WARRANTY ...............................40
Please read this manual and the enclosed safety materials carefully!
Fasten the manual near the garage door after installation.
The door WILL NOT CLOSE unless the Protector System
®
is connected and properly
aligned.
Periodic checks of the garage door opener are required to ensure safe operation.
The model number label is located on the left side panel of your garage door opener.
This garage door opener is ONLY compatible with MyQ and Security 2.0
TM
accessories.
DO NOT enable the Timer-To-Close feature if you are installing the garage door
opener on a one-piece door. The Timer -To-Close is to be used ONLY with
sectional doors.
.
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - Model 8550RGD

Serial Number:Date of Purchase: Belt Drive Garage Door OpenerRaynor Garage Doors1101 E. River RoadDixon, Illinois 61021www.raynor.comWrite down the fo

Seite 2 - Preparation

10To avoid possible SERIOUS INJURY from afalling garage door opener,fasten it SECURELY tostructural supports of the garage.Concrete anchorsMUSTbe used

Seite 3

11To preventpossible OVERHEATING of the end panel or light socket:• Use ONLY A19 incandescent or compactfluorescent light bulbs.• DO NOT use incandesc

Seite 4 - Assembly

12Fiberglass,aluminum or lightweightsteel garage doors WILLREQUIRE reinforcement BEFOREinstallation of door bracket.Contact your door manufacturer fo

Seite 5 - 2 Tighten the Belt

13IMPORTANT: The groove on the straight door arm MUST face away from the curved door arm.Straight Door ArmCurved DoorArm(Groove facing out)CORRECTINCO

Seite 6

141 Install the door controlInstall the Door ControlTo preventpossible SERIOUS INJURY or DEATHfrom electrocution:• Be sure power is NOT connected BEFO

Seite 7

15kInstall the Door Control1.5 Position the bottom hole of the doorcontrol over the screw and slidedown into place.1.6 Lift the push bar up and mark t

Seite 8

163 Attach the warning labelsInstall the Door Control3.1 Attach the entrapment warning label on the wall near the door control with tacks orstaples.3.

Seite 9 - HARDWARE

17IntroductionBe sure power is NOT connected to the garagedoor opener BEFORE installing the safetyreversing sensor.To preventSERIOUS INJURY or DEATH f

Seite 10 - Installation

Install the Protector System®1 Install the Safety Reversing SensorsThe safety reversing sensors can be attached to the door track,the wall, or the flo

Seite 11 - 6 Install the light bulbs

Install the Protector System®1 Install the Safety Reversing SensorsOPTION CFLOOR INSTALLATIONUse an extension bracket (notprovided) or wood black to r

Seite 12 - 8 Install the door bracket

2Safety Symbol and SignalWord ReviewThis garage door opener has been designed andtested to offer safe service provided it is installed,operated, maint

Seite 13 - Trolley

Install the Protector System®OPTION B PRE-WIRED INSTALLATION2.1B Cut the end of the safetyreversing sensor wire, makingsure there is enough wire torea

Seite 14 - Install the Door Control

211 Connect PowerTo preventpossible SERIOUS INJURY orDEATHfrom electrocution or fire:• Be sure power is NOT connected to theopener, and disconnectpowe

Seite 15

222 Ensure the Safety Reversing Sensors are alignedThe door will not close if the sensors have not beeninstalled and aligned correctly.When the lightb

Seite 16 - 3 Attach the warning labels

23Without a properly installed safety reversalsystem, persons (particularly small children)could be SERIOUSLY INJURED or KILLED by aclosing garage doo

Seite 17 - Install the Protector System

241 Program theTravelWithout a properly installed safety reversal system,persons (particularlysmall children) could be SERIOUSLY INJURED or KILLED by

Seite 18

252 Test the Safety Reversal SystemWithout a properly installed safety reversal system,persons (particularly small children) could beSERIOUSLY INJURED

Seite 19

26To reduce the riskofFIRE or INJURY to persons:• DisconnectALL electric and battery powerBEFORE performing ANY service ormaintenance.• Use ONLY Rayno

Seite 20

27BATTERY STATUS LEDNOTE: The Battery Status LED is most visiblewith the garage door opener light off. Batterydoes not have to be fully charged to ope

Seite 21 - OPTION B

28IMPORTANT SAFETYINSTRUCTIONSWARNING To reduce the risk of SEVERE INJURY or DEATH:1. READ AND FOLLOW ALL WARNINGS ANDINSTRUCTIONS.2. ALWAYS keep rem

Seite 22

29Your garage door opener is equipped with features to provide you with greater control over yourgarage door operation.TIMER-TO-CLOSEThe Timer-to-Clos

Seite 23 - Adjustments

3ABCJNIOPDEFHGKLMOverview/Carton InventoryGARAGE DOOR OPENER ASSEMBLYA. tekcarb redaeH B. Pulley and bracketC. tekcarb rooD D. mra rood devruC E.

Seite 24

30USING THE DOOR CONTROLSYNCHRONIZETHEDOORCONTROLTo synchronize the door control to the garage door opener,pressthe push bar until the garage dooro

Seite 25

31MENU NAVIGATIONThe features on the door control can be programmed through a seriesofmenuson the screen and the navigation buttons.Refer to the descr

Seite 26 - Battery Backup

32Your garage door opener has been programmed at the factory to operate with your remote control. To programadditional remote controls refer to the in

Seite 27

333 Using a safety pin or paper clip,presstheprogram button until the LEDson the front ofthe remote control turn on.4 Press and release the Learn butt

Seite 28 - WARNING

34To prevent possible SERIOUS INJURY or DEATH from a falling garage door:• Ifpossible, use emergency release handle to disengage trolley ONLY when gar

Seite 29 - Features

35Diagnostic ChartYour garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener flash the

Seite 30 - Door Control

36DIAGNOSTICCODEUPARROWFLASH(ES)DOWNARROWFLASH(ES)SYMPTOM CAUSE RESOLUTION3-3 3 3The garage door opener isidle and the battery LEDisconstantlyflashing

Seite 31

37Rail Assembly PartsDESCRIPTION PART NUMBER1 Belt - for 7 foot doorBelt - for 8 foot doorBelt - for 10 foot door41A5434-1141A5434-1341A5434-142 Belt

Seite 32 - Remote Control

38Garage Door Opener Parts11124101953627843DESCRIPTION PART NUMBER1 Sprocket and Sprocket Cover withScrews41C589-22 End Panel with labels, battery cov

Seite 33

828LG MyQ™ Internet Gateway:Internet enabled accessorywhich connectsto the computerand allows you to monitor andcontrol garage door openersand lightin

Seite 34 - To Open the Door Manually

4To avoid possible SERIOUS INJURY to fingerfrom moving garage door opener:• ALWAYS keep hand clear of sprocketwhileoperating opener.• Securelyattach s

Seite 35 - Troubleshooting

RAYNOR®FIVE YEAR LIMITED WARRANTYLIFETIME MOTOR AND BELT LIMITED WARRANTYONE YEAR LIMITED WARRANTY FOR THEBATTERYBACK-UPRaynor®(“Seller”) warrantsto

Seite 36

52 Tighten the Belt2.1 By hand, thread the spring trolleynut on the threaded shaftuntil it isfinger tight againstthe trolley.Do notuse any tools.Sprin

Seite 37 - Repair Parts

6IMPORTANT INSTALLATION INSTRUCTIONSWARNING To reduce the risk of SEVERE INJURY or DEATH:1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS

Seite 38

7To prevent possible SERIOUS INJURY orDEATH:• Header bracket MUST be RIGIDLYfastened to structural supporton headerwall or ceiling,otherwise garage do

Seite 39 - Accessories

8You can attach the header bracketeither to thewall above the garage door, or to the ceiling.Follow the instructionswhich will work best foryour parti

Seite 40 - Warranty

93.1 Align the rail with the header bracket.Insert the clevispin (H5) through theholesin the header bracketand rail.Secure with the ring fastener (H11

Kommentare zu diesen Handbüchern

Keine Kommentare